235 lines
8.6 KiB
Vue
235 lines
8.6 KiB
Vue
/**
|
|
* @license
|
|
* Copyright 2015 The Emscripten Authors
|
|
* SPDX-License-Identifier: MIT
|
|
*/
|
|
|
|
// Pthread Web Worker startup routine:
|
|
// This is the entry point file that is loaded first by each Web Worker
|
|
// that executes pthreads on the Emscripten application.
|
|
|
|
// Thread-local:
|
|
var initializedJS = false; // Guard variable for one-time init of the JS state (currently only embind types registration)
|
|
|
|
var Module = {};
|
|
|
|
function assert(condition, text) {
|
|
if (!condition) abort('Assertion failed: ' + text);
|
|
}
|
|
|
|
function threadPrintErr() {
|
|
var text = Array.prototype.slice.call(arguments).join(' ');
|
|
console.error(text);
|
|
}
|
|
function threadAlert() {
|
|
var text = Array.prototype.slice.call(arguments).join(' ');
|
|
postMessage({cmd: 'alert', text: text, threadId: Module['_pthread_self']()});
|
|
}
|
|
// We don't need out() for now, but may need to add it if we want to use it
|
|
// here. Or, if this code all moves into the main JS, that problem will go
|
|
// away. (For now, adding it here increases code size for no benefit.)
|
|
var out = function() {
|
|
throw 'out() is not defined in worker.js.';
|
|
}
|
|
var err = threadPrintErr;
|
|
this.alert = threadAlert;
|
|
|
|
Module['instantiateWasm'] = function(info, receiveInstance) {
|
|
// Instantiate from the module posted from the main thread.
|
|
// We can just use sync instantiation in the worker.
|
|
var instance = new WebAssembly.Instance(Module['wasmModule'], info);
|
|
// TODO: Due to Closure regression https://github.com/google/closure-compiler/issues/3193,
|
|
// the above line no longer optimizes out down to the following line.
|
|
// When the regression is fixed, we can remove this if/else.
|
|
receiveInstance(instance);
|
|
// We don't need the module anymore; new threads will be spawned from the main thread.
|
|
Module['wasmModule'] = null;
|
|
return instance.exports;
|
|
};
|
|
|
|
function moduleLoaded() {
|
|
}
|
|
|
|
this.onmessage = function(e) {
|
|
try {
|
|
if (e.data.cmd === 'load') { // Preload command that is called once per worker to parse and load the Emscripten code.
|
|
|
|
// Module and memory were sent from main thread
|
|
Module['wasmModule'] = e.data.wasmModule;
|
|
|
|
Module['wasmMemory'] = e.data.wasmMemory;
|
|
|
|
Module['buffer'] = Module['wasmMemory'].buffer;
|
|
|
|
Module['ENVIRONMENT_IS_PTHREAD'] = true;
|
|
|
|
if (typeof e.data.urlOrBlob === 'string') {
|
|
importScripts(e.data.urlOrBlob);
|
|
} else {
|
|
var objectUrl = URL.createObjectURL(e.data.urlOrBlob);
|
|
importScripts(objectUrl);
|
|
URL.revokeObjectURL(objectUrl);
|
|
}
|
|
JSAudioInterComModule(Module).then(function (instance) {
|
|
Module = instance;
|
|
moduleLoaded();
|
|
});
|
|
|
|
} else if (e.data.cmd === 'objectTransfer') {
|
|
Module['PThread'].receiveObjectTransfer(e.data);
|
|
} else if (e.data.cmd === 'run') {
|
|
// This worker was idle, and now should start executing its pthread entry
|
|
// point.
|
|
// performance.now() is specced to return a wallclock time in msecs since
|
|
// that Web Worker/main thread launched. However for pthreads this can
|
|
// cause subtle problems in emscripten_get_now() as this essentially
|
|
// would measure time from pthread_create(), meaning that the clocks
|
|
// between each threads would be wildly out of sync. Therefore sync all
|
|
// pthreads to the clock on the main browser thread, so that different
|
|
// threads see a somewhat coherent clock across each of them
|
|
// (+/- 0.1msecs in testing).
|
|
Module['__performance_now_clock_drift'] = performance.now() - e.data.time;
|
|
|
|
// Pass the thread address inside the asm.js scope to store it for fast access that avoids the need for a FFI out.
|
|
Module['__emscripten_thread_init'](e.data.threadInfoStruct, /*isMainBrowserThread=*/0, /*isMainRuntimeThread=*/0);
|
|
|
|
// Establish the stack frame for this thread in global scope
|
|
// The stack grows downwards
|
|
var max = e.data.stackBase;
|
|
var top = e.data.stackBase + e.data.stackSize;
|
|
assert(e.data.threadInfoStruct);
|
|
assert(top != 0);
|
|
assert(max != 0);
|
|
assert(top > max);
|
|
// Also call inside JS module to set up the stack frame for this pthread in JS module scope
|
|
Module['establishStackSpace'](top, max);
|
|
Module['PThread'].receiveObjectTransfer(e.data);
|
|
Module['PThread'].threadInit();
|
|
|
|
// Embind must initialize itself on all threads, as it generates support JS.
|
|
// We only do this once per worker since they get reused
|
|
if (!initializedJS) {
|
|
Module['___embind_register_native_and_builtin_types']();
|
|
initializedJS = true;
|
|
}
|
|
|
|
try {
|
|
// pthread entry points are always of signature 'void *ThreadMain(void *arg)'
|
|
// Native codebases sometimes spawn threads with other thread entry point signatures,
|
|
// such as void ThreadMain(void *arg), void *ThreadMain(), or void ThreadMain().
|
|
// That is not acceptable per C/C++ specification, but x86 compiler ABI extensions
|
|
// enable that to work. If you find the following line to crash, either change the signature
|
|
// to "proper" void *ThreadMain(void *arg) form, or try linking with the Emscripten linker
|
|
// flag -s EMULATE_FUNCTION_POINTER_CASTS=1 to add in emulation for this x86 ABI extension.
|
|
var result = Module['invokeEntryPoint'](e.data.start_routine, e.data.arg);
|
|
|
|
Module['checkStackCookie']();
|
|
if (Module['keepRuntimeAlive']()) {
|
|
Module['PThread'].setExitStatus(result);
|
|
} else {
|
|
Module['PThread'].threadExit(result);
|
|
}
|
|
} catch(ex) {
|
|
if (ex === 'Canceled!') {
|
|
Module['PThread'].threadCancel();
|
|
} else if (ex != 'unwind') {
|
|
// FIXME(sbc): Figure out if this is still needed or useful. Its not
|
|
// clear to me how this check could ever fail. In order to get into
|
|
// this try/catch block at all we have already called bunch of
|
|
// functions on `Module`.. why is this one special?
|
|
if (typeof(Module['_emscripten_futex_wake']) !== "function") {
|
|
err("Thread Initialisation failed.");
|
|
throw ex;
|
|
}
|
|
// ExitStatus not present in MINIMAL_RUNTIME
|
|
if (ex instanceof Module['ExitStatus']) {
|
|
if (Module['keepRuntimeAlive']()) {
|
|
err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' called exit(), staying alive due to noExitRuntime.');
|
|
} else {
|
|
err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' called exit(), calling threadExit.');
|
|
Module['PThread'].threadExit(ex.status);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
Module['PThread'].threadExit(-2);
|
|
throw ex;
|
|
}
|
|
} else {
|
|
// else e == 'unwind', and we should fall through here and keep the pthread alive for asynchronous events.
|
|
err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' completed its pthread main entry point with an unwind, keeping the pthread worker alive for asynchronous operation.');
|
|
}
|
|
}
|
|
} else if (e.data.cmd === 'cancel') { // Main thread is asking for a pthread_cancel() on this thread.
|
|
if (Module['_pthread_self']()) {
|
|
Module['PThread'].threadCancel();
|
|
}
|
|
} else if (e.data.target === 'setimmediate') {
|
|
// no-op
|
|
} else if (e.data.cmd === 'processThreadQueue') {
|
|
if (Module['_pthread_self']()) { // If this thread is actually running?
|
|
Module['_emscripten_current_thread_process_queued_calls']();
|
|
}
|
|
} else {
|
|
err('worker.js received unknown command ' + e.data.cmd);
|
|
err(e.data);
|
|
}
|
|
} catch(ex) {
|
|
err('worker.js onmessage() captured an uncaught exception: ' + ex);
|
|
if (ex && ex.stack) err(ex.stack);
|
|
throw ex;
|
|
}
|
|
};
|
|
|
|
// Node.js support
|
|
if (typeof process === 'object' && typeof process.versions === 'object' && typeof process.versions.node === 'string') {
|
|
// Create as web-worker-like an environment as we can.
|
|
self = {
|
|
location: {
|
|
href: __filename
|
|
}
|
|
};
|
|
|
|
var onmessage = this.onmessage;
|
|
|
|
var nodeWorkerThreads = require('worker_threads');
|
|
|
|
global.Worker = nodeWorkerThreads.Worker;
|
|
|
|
var parentPort = nodeWorkerThreads.parentPort;
|
|
|
|
parentPort.on('message', function(data) {
|
|
onmessage({ data: data });
|
|
});
|
|
|
|
var nodeFS = require('fs');
|
|
|
|
var nodeRead = function(filename) {
|
|
return nodeFS.readFileSync(filename, 'utf8');
|
|
};
|
|
|
|
function globalEval(x) {
|
|
global.require = require;
|
|
global.Module = Module;
|
|
eval.call(null, x);
|
|
}
|
|
|
|
importScripts = function(f) {
|
|
globalEval(nodeRead(f));
|
|
};
|
|
|
|
postMessage = function(msg) {
|
|
parentPort.postMessage(msg);
|
|
};
|
|
|
|
if (typeof performance === 'undefined') {
|
|
performance = {
|
|
now: function() {
|
|
return Date.now();
|
|
}
|
|
};
|
|
}
|
|
}
|
|
|
|
|